The hydro facial machine with solution bottles integrates a negative-pressure vacuum system with independent multi-channel fluid delivery. The platform performs extraction and topical infusion via medical-grade fluid pathways. Driven by an industrial-grade oil-free diaphragm pump and dual-core control microprocessors, the system maintains consistent suction performance and fluid output under operational use.
Key Features
Quad-Bottle Independent Fluid Management: Features four dedicated, color-coded medical-grade solution bottles (Bottle A/B/C/D) and a separate waste recovery tank, segregating active serums (AHA, BHA, peptides, antioxidants) to prevent cross-contamination.
Precision Vacuum Regulation: Adjustable negative pressure range of 0 to 90 kPa, monitored via a digital pressure display to match varying treatment parameters.
Six-Modality Modular Configuration: Integrated architecture supporting Hydro-dermabrasion, Multipolar RF (1MHz), Ultrasonic Scrubber (28kHz), Ultrasound Infusion (1.1MHz), Cryogenic Cold Hammer, and Oxygen Atomization Spray.
Microprocessor Flow Control: Peristaltic pumps regulate liquid volume delivery per second based on preset operator input.
Sanitary Quick-Connect Tubing: Push-to-connect medical silicone fittings allow tool-free disassembly for routine chemical sanitization of internal fluid circuits.
Technical Specifications
|
Parameter |
Specification |
|
Input Voltage |
AC 110V-240V, 50Hz/60Hz |
|
Power Consumption |
Max 180W |
|
Vacuum Pressure |
0 ~ 90 kPa (Digitally Adjustable via Touch Interface) |
|
Solution Capacity |
400 ml per bottle (4 functional tanks + 1 waste tank) |
|
Bottle Material |
Medical-grade PCTG (BPA-free, chemical and corrosion resistant) |
|
RF Frequency |
1 MHz - 3 MHz (Multipolar configuration) |
|
Ultrasound Frequency |
1.1 MHz (Facial handpiece) / 28 kHz (Skin scrubber) |
|
Cryo Cooling Temperature |
-5°C to 5°C (Regulated cold hammer handpiece) |
|
Display Interface |
10.4-inch True Color Capacitive Touch Screen |
|
Chassis Construction |
ABS Engineering Plastic with Anti-UV and Scratch-Resistant Finish |
|
Net Weight |
24 kg |
|
Dimensions |
450 mm x 420 mm x 1150 mm (Floor-standing unit) |
Operating Modes
Preset Clinical Protocols: Factory-programmed parameter configurations establishing baseline vacuum levels, fluid output rates, and energy settings for standard treatment workflows.
Manual Custom Mode: Independent parameter adjustment interface enabling operators to control suction pressure, serum flow volume (Levels 1-5), and energy frequency based on individual treatment requirements.
Applications
Sebum & Comedone Extraction: Softens keratin structures and extracts impurities from sebaceous ducts using hydrodynamic suction pressure.
Controlled Epidermal Exfoliation: Delivers diluted glycolic, lactic, or salicylic acid solutions while simultaneously vacuuming liquid and exfoliated matter into the waste recovery tank.
Transdermal Infusion: Employs low-frequency ultrasound and hydrodynamic pressure to facilitate the delivery of water-soluble active compounds across the stratum corneum.
Vasoconstriction & Calming: Cryogenic cold-hammer application lowers skin surface temperature post-treatment to constrict local capillaries and reduce transient erythema.
OEM & ODM Customization Services
As a direct manufacturing facility, we support customization programs for aesthetic device brands, regional distributors, and clinic chains:
Software & UI Development: Boot logo integration, localized language support, and customized treatment parameter boundaries.
Industrial Design & Enclosure: Color matching, custom outer casing mold adaptations, and laser-engraved identification plates.
Fluid Circuit Compatibility: Manifold configurations engineered for compatibility with specific active cosmetic formulations upon chemical testing.
Regulatory Technical Files: Provision of technical documentation dossiers to support local market compliance filing (e.g., CE technical construction files, ISO conformity records).
Quality Control & Manufacturing Verification
Every production batch undergoes standard factory inspection protocols prior to dispatch:
Facility & System Standards: Manufactured under ISO 13485 (Medical Devices Quality Management Systems) and ISO 9001 certified operational guidelines.
Compliance Certifications: CE Conformity (LVD Directive 2014/35/EU, EMC Directive 2014/30/EU), RoHS compliant internal wiring harnesses.
Factory Inspection Protocol:
Pump Aging Test: 100% of vacuum pumps undergo a minimum 48-hour continuous run-test prior to final assembly.
Electrical Safety Testing: Dielectric strength and leakage current testing executed on every finished unit in accordance with IEC 60601 safety protocols.
Hydraulic Pressure Test: Pressurized fluid-circuit inspection to verify zero internal leakage prior to packaging.
Packaging & Logistics
Inner Cushioning: Custom high-density EPE molded foam inserts contoured precisely to mainframe and handpiece dimensions to absorb transit vibration.
Outer Cartoning: 5-layer export-grade corrugated honeycomb master carton sealed with waterproof PE film wrapping (Custom wooden crating available for sea freight pallet shipments).
Standard Package Contents:
1 x Mainframe Unit
6 x Functional Handpieces
4 x Solution Bottles + 1 x Waste Recovery Bottle
1 x Detachable Power Cord
1 x Silicone Tubing & O-Ring Spares Kit
1 x Technical User & Maintenance Manual
Shipping Terms: EXW, FOB, CIF supported via air express (sample evaluation) or sea freight (palletized LCL/FCL bulk orders).
Frequently Asked Questions
Q: What is the recommended daily maintenance protocol for the fluid system?
A: Flush internal tubing with clean distilled water or a dedicated system-cleaning solution immediately following the final treatment session of the day. Conduct periodic sanitization using a medical-grade low-concentration disinfectant to maintain hygiene standards.
Q: Are replacement wear-and-tear parts available for ongoing supply?
A: Yes. Replaceable consumable parts-including PCTG solution bottles, silicone sealing rings, diamond abrasion tips, and plastic suction heads-are maintained in stock for wholesale dispatch.
Q: What is the standard production lead time for custom OEM orders?
A: Standard production lead time is 25 to 35 business days following final artwork approval, UI customization sign-off, and receipt of the manufacturing deposit.
Q: Does the equipment require specialized electrical wiring or installation?
A: No. The unit operates on standard single-phase commercial power inputs (110V/220V) and features built-in electrical surge protection and power line filtering.
Request a Factory Quotation
Submit your project parameters to receive a formal wholesale or OEM quotation from our engineering and sales team within 24 business hours.
Inquiry Checklist:
Company Name / Corporate Website
Intended Order Volume (Sample trial MOQ starts at 1 unit; OEM custom branding MOQ starts at 10 units)
Destination Port / Delivery Location
Specific Technical or Customization Requirements (e.g., UI language, Voltage specification, Enclosure color)
Button: Submit RFQ / Connect with Engineering Team